Abstract
Four double-gap CMS resistive plate chambers are being tested at the CERN Gamma Irradiation Facility to determine the performance and aging effects at the expected conditions of the High Luminosity-Large Hadron Collider. Results up to an integrated charge of 290 millicoulomb/cm2 are reported.
Original language | English |
---|---|
Article number | P08024 |
Journal | Journal of Instrumentation |
Volume | 13 |
Issue number | 8 |
DOIs | |
Publication status | Published - Aug 30 2018 |
Keywords
- Gaseous detectors
- Resistive-plate chambers
ASJC Scopus subject areas
- Instrumentation
- Mathematical Physics
Access to Document
Other files and links
Cite this
- APA
- Standard
- Harvard
- Vancouver
- Author
- BIBTEX
- RIS
In: Journal of Instrumentation, Vol. 13, No. 8, P08024, 30.08.2018.
Research output: Contribution to journal › Article › peer-review
}
TY - JOUR
T1 - Long-term performance and longevity studies of the CMS Resistive Plate Chambers
AU - Rabadan-Trejo, R. I.
AU - Fagot, A.
AU - Gul, M.
AU - Roskas, C.
AU - Tytgat, M.
AU - Zaganidis, N.
AU - Souza, S. Fonseca De
AU - Santoro, A.
AU - Araujo, F. Torres Da Silva De
AU - Aleksandrov, A.
AU - Hadjiiska, R.
AU - Iaydjiev, P.
AU - Rodozov, M.
AU - Shopova, M.
AU - Sultanov, G.
AU - Dimitrov, A.
AU - Litov, L.
AU - Pavlov, B.
AU - Petkov, P.
AU - Petrov, A.
AU - Qian, S. J.
AU - Han, D.
AU - Yi, W.
AU - Avila, C.
AU - Cabrera, A.
AU - Carrillo, C.
AU - Segura, M.
AU - Aly, S.
AU - Assran, Y.
AU - Mahrous, A.
AU - Mohamed, A.
AU - Combaret, C.
AU - Gouzevitch, M.
AU - Grenier, G.
AU - Lagarde, F.
AU - Laktineh, I. B.
AU - Mathez, H.
AU - Mirabito, L.
AU - Shchablo, K.
AU - Bagaturia, I.
AU - Lomidze, D.
AU - Lomidze, I.
AU - Pant, L. M.
AU - Bhatnagar, V.
AU - Gupta, R.
AU - Kumari, R.
AU - Lohan, M.
AU - Singh, J. B.
AU - Amoozegar, V.
AU - Boghrati, B.
AU - Ghasemy, H.
AU - Malmir, S.
AU - Najafabadi, M. Mohammadi
AU - Abbrescia, M.
AU - Gelmi, A.
AU - Iaselli, G.
AU - Lezki, S.
AU - Pugliese, G.
AU - Benussi, L.
AU - Bianco, S.
AU - Piccolo, D.
AU - Primavera, F.
AU - Buontempo, S.
AU - Crescenzo, A.
AU - Galati, G.
AU - Fienga, F.
AU - Orso, I.
AU - Lista, L.
AU - Meola, S.
AU - Paolucci, P.
AU - Voevodina, E.
AU - Braghieri, A.
AU - Montagna, P.
AU - Ressegotti, M.
AU - Riccardi, C.
AU - Salvini, P.
AU - Vitulo, P.
AU - Cho, S. W.
AU - Choi, S. Y.
AU - Hong, B.
AU - Lee, K. S.
AU - Lim, J. H.
AU - Park, S. K.
AU - Goh, J.
AU - Kim, T. J.
AU - Moreno, S. Carrillo
AU - Colin, O. Miguel
AU - Valencia, F. Vazquez
AU - Bernardino, S. Carpinteyro
AU - Eysermans, J.
AU - Pedraza, I.
AU - Estrada, C. Uribe
AU - Reyes-Almanza, R.
AU - Duran-Osuna, M. C.
AU - Ramirez-Garcia, M.
AU - Ramirez-Sanchez, G.
AU - Sanchez-Hernandez, A.
AU - Castilla-Valdez, H.
AU - Radi, A.
AU - Hoorani, H.
AU - Muhammad, S.
AU - Shah, M. A.
AU - Crotty, I.
N1 - Funding Information: aGhent University, Department of Physics and Astronomy, Proeftuinstraat 86, B-9000 Ghent, Belgium bDepartamento de Fisica Nuclear e Altas Energias, Instituto de Fisica, Universidade do Estado do Rio de Janeiro, Rua Sao Francisco Xavier, 524, BR - Rio de Janeiro 20559-900, RJ, Brazil cBulgarian Academy of Sciences, Institute for Nuclear Research and Nuclear Energy, Tzarigradsko shaussee Boulevard 72, BG-1784 Sofia, Bulgaria dFaculty of Physics, University of Sofia, 5 James Bourchier Boulevard, BG-1164 Sofia, Bulgaria eSchool of Physics, Peking University, Beijing 100871, China fTsinghua University, Shuangqing Rd, Haidian Qu, Beijing, China gUniversidad de Los Andes, Apartado Aereo 4976, Carrera 1E, no. 18A 10, CO-Bogota, Colombia hEgyptian Network for High Energy Physics, Academy of Scientific Research and Technology, 101 Kasr El-Einy St. Cairo Egypt Publisher Copyright: © 2018 CERN.
PY - 2018/8/30
Y1 - 2018/8/30
N2 - Four double-gap CMS resistive plate chambers are being tested at the CERN Gamma Irradiation Facility to determine the performance and aging effects at the expected conditions of the High Luminosity-Large Hadron Collider. Results up to an integrated charge of 290 millicoulomb/cm2 are reported.
AB - Four double-gap CMS resistive plate chambers are being tested at the CERN Gamma Irradiation Facility to determine the performance and aging effects at the expected conditions of the High Luminosity-Large Hadron Collider. Results up to an integrated charge of 290 millicoulomb/cm2 are reported.
KW - Gaseous detectors
KW - Resistive-plate chambers
UR - http://www.scopus.com/inward/record.url?scp=85053111939&partnerID=8YFLogxK
UR - http://www.scopus.com/inward/citedby.url?scp=85053111939&partnerID=8YFLogxK
U2 - 10.1088/1748-0221/13/08/P08024
DO - 10.1088/1748-0221/13/08/P08024
M3 - Article
AN - SCOPUS:85053111939
SN - 1748-0221
VL - 13
JO - Journal of Instrumentation
JF - Journal of Instrumentation
IS - 8
M1 - P08024
ER -