TY - JOUR
T1 - Characterizing leachate contamination in a landfill site using Time Domain Electromagnetic (TDEM) imaging
AU - Baawain, Mahad S.
AU - Al-Futaisi, Ahmed M.
AU - Ebrahimi, A.
AU - Omidvarborna, Hamid
PY - 2018/4
Y1 - 2018/4
N2 - Time Domain Electromagnetic (TDEM) survey as well as drilling investigations were conducted to identify possible contamination of a dumping site in an unsaturated zone located in Barka, Oman. The method was applied to evaluate conductivity of the contaminated plumes in hot and arid/semiarid region, where high temperatures commonly ranged between 35 and 50 °C. The drilling investigation was carried out over the survey area to verify the geophysical results. The low-resistivity zone (<80 Ωm), encountered near the subsurface, indicated plume migration caused by liquid waste disposal activities. The combination of TDEM survey results with the lithology of piezometers showed that higher resistivity (>90 Ωm) was correlated with compacted or cemented gravels and cobbles, particularly that of medium dense to very dense gravels and cobbles. Additionally, the TDEM profiles suggested that the plume migration followed a preferential flow path. The resistivity range 40–80 Ωm considered as contaminated areas; however, the drilling results showed the close resistivity domain in the depth >70 m below water table for some profiles (BL1, BL2, BL3, BL4 and BL5). The combined results of drilling wells, piezometers, and TDEM apparent resistivity maps showed a coincidence of the migrated leachate plume and water table. Predicted zone of the probable contamination was located at the depth of around 65 m and horizontal offset ranges 0–280 m, 80–240 m, and 40–85 m in the sounding traverses of BL4, BL6 and BL7, respectively.
AB - Time Domain Electromagnetic (TDEM) survey as well as drilling investigations were conducted to identify possible contamination of a dumping site in an unsaturated zone located in Barka, Oman. The method was applied to evaluate conductivity of the contaminated plumes in hot and arid/semiarid region, where high temperatures commonly ranged between 35 and 50 °C. The drilling investigation was carried out over the survey area to verify the geophysical results. The low-resistivity zone (<80 Ωm), encountered near the subsurface, indicated plume migration caused by liquid waste disposal activities. The combination of TDEM survey results with the lithology of piezometers showed that higher resistivity (>90 Ωm) was correlated with compacted or cemented gravels and cobbles, particularly that of medium dense to very dense gravels and cobbles. Additionally, the TDEM profiles suggested that the plume migration followed a preferential flow path. The resistivity range 40–80 Ωm considered as contaminated areas; however, the drilling results showed the close resistivity domain in the depth >70 m below water table for some profiles (BL1, BL2, BL3, BL4 and BL5). The combined results of drilling wells, piezometers, and TDEM apparent resistivity maps showed a coincidence of the migrated leachate plume and water table. Predicted zone of the probable contamination was located at the depth of around 65 m and horizontal offset ranges 0–280 m, 80–240 m, and 40–85 m in the sounding traverses of BL4, BL6 and BL7, respectively.
KW - Geophysical survey
KW - Groundwater contamination
KW - Plume migration
KW - Time Domain Electromagnetic (TDEM)
KW - Unsaturated zone
UR - http://www.scopus.com/inward/record.url?scp=85042303939&partnerID=8YFLogxK
UR - http://www.scopus.com/inward/citedby.url?scp=85042303939&partnerID=8YFLogxK
U2 - 10.1016/j.jappgeo.2018.02.002
DO - 10.1016/j.jappgeo.2018.02.002
M3 - Article
AN - SCOPUS:85042303939
SN - 0926-9851
VL - 151
SP - 73
EP - 81
JO - Journal of Applied Geophysics
JF - Journal of Applied Geophysics
ER -