T1 - مقارنة بین الكود العماني لتصمیم المباني ضد مخاطر الزلازل مع نظیراتھا الدولیة بناءً على المخاطر الزلزالیة الإقلیمیة
AU - Waris, Muhammad Bilal
AU - Al-Jabri, Khalifa
AU - El-Hussain, Issa
N1 - Publisher Copyright:
© 2022. Journal of Engineering Research. All Rights Reserved.
PY - 2022
Y1 - 2022
N2 - This study compares the Oman Seismic Code (OSC) developed in 2013 with the Uniform Building Code 1997 (UBC) and the International Building Code 2006 (IBC) that are frequently used for seismic analysis and design in Oman. Base shear, story shear force distribution, and story drift ratios are compared using the equivalent static load and the response spectrum analysis methods. The discussion considers reinforced concrete buildings having a footprint of 25m × 40m with heights of 10 m, 19 m, 40 m, and 58m having 3-, 6-, 13 and 19-stories, respectively. The buildings are considered as supported on very dense soil (type C) and have normal occupancy conditions. The Zone-1 of OSC is compared with the Zone-1 of UBC and IBC considering the low and the normal ductility class definitions of OSC. For the low ductility class, the values of design base shear for different building heights from IBC are 82% for the equivalent static method and ranged between 83%-85% for the response spectrum method compared to OSC. The base shear values by UBC are 73%-81% and 75%-78% for the equivalent static and the response spectrum methods, respectively, in comparison to OSC. For normal ductility class, IBC and UBC estimates are higher than OSC for all building heights except for the 3-story building. The story shear forces and story drift ratios from OSC also compared well with the international counterparts. The comparison indicates that Zone-1 in OSC is well matched to Zone-1 of UBC and IBC.
AB - This study compares the Oman Seismic Code (OSC) developed in 2013 with the Uniform Building Code 1997 (UBC) and the International Building Code 2006 (IBC) that are frequently used for seismic analysis and design in Oman. Base shear, story shear force distribution, and story drift ratios are compared using the equivalent static load and the response spectrum analysis methods. The discussion considers reinforced concrete buildings having a footprint of 25m × 40m with heights of 10 m, 19 m, 40 m, and 58m having 3-, 6-, 13 and 19-stories, respectively. The buildings are considered as supported on very dense soil (type C) and have normal occupancy conditions. The Zone-1 of OSC is compared with the Zone-1 of UBC and IBC considering the low and the normal ductility class definitions of OSC. For the low ductility class, the values of design base shear for different building heights from IBC are 82% for the equivalent static method and ranged between 83%-85% for the response spectrum method compared to OSC. The base shear values by UBC are 73%-81% and 75%-78% for the equivalent static and the response spectrum methods, respectively, in comparison to OSC. For normal ductility class, IBC and UBC estimates are higher than OSC for all building heights except for the 3-story building. The story shear forces and story drift ratios from OSC also compared well with the international counterparts. The comparison indicates that Zone-1 in OSC is well matched to Zone-1 of UBC and IBC.
KW - Equivalent static load method
KW - International building code (ibc)
KW - Oman seismic code
KW - Response spectrum analysis
KW - Uniform building code (ubc)
UR - http://www.scopus.com/inward/record.url?scp=85129270934&partnerID=8YFLogxK
UR - http://www.scopus.com/inward/citedby.url?scp=85129270934&partnerID=8YFLogxK
U2 - 10.53540/tjer.vol19iss1pp1-12
DO - 10.53540/tjer.vol19iss1pp1-12
M3 - Article
AN - SCOPUS:85129270934
SN - 1726-6009
VL - 19
JO - Journal of Engineering Research
JF - Journal of Engineering Research
IS - 1
ER -