ملخص
The stability of a horizontal layer of Boussinesq fluid, heated from below and cooled from above, rotating uniformly about the vertical in the presence of a uniform vertical magnetic field is studied for the case where the thermal diffusivity K is much larger than the magnetic diffusivity n (= l/μlδe where μ is the magnetic permeability and μ, is the electrical conductivity). The stability problem depends on the five dimensionless numbers Ra, T, M, q, qb. The Rayleigh number, Ra, is a measure of the buoyancy force, the Taylor number, T, is a measure of the Coriolis force, the Hartmann number, M, is a measure of the Lorentz force and q=k/n, while qb=Kμδb, where ub is the electrical conductivity of the boundary.
اللغة الأصلية | English |
---|---|
الصفحات (من إلى) | 213-231 |
عدد الصفحات | 19 |
دورية | Geophysical and Astrophysical Fluid Dynamics |
مستوى الصوت | 41 |
رقم الإصدار | 3-4 |
المعرِّفات الرقمية للأشياء | |
حالة النشر | Published - 1988 |
ASJC Scopus subject areas
- ???subjectarea.asjc.1900.1906???
- ???subjectarea.asjc.1900.1908???
- ???subjectarea.asjc.2200.2206???
- ???subjectarea.asjc.3100.3103???
- ???subjectarea.asjc.2200.2211???