TY - JOUR
T1 - Spectrofluorimetric determination of aluminium in water samples using N-((2-hydroxynaphthalen-1-yl)methylene) acetylhydrazide
AU - Al-Kindy, Salma M.Z.
AU - Al-Hinai, Aamna
AU - Al-Rasbi, Nawal K.
AU - Suliman, Fakhr Eldin O.
AU - Al Lawati, Haider
N1 - Funding Information:
The authors thank the Department of Chemistry, Sultan Qaboos University for the financial support to carry out this work.
Publisher Copyright:
© 2015 Taibah University.
PY - 2015
Y1 - 2015
N2 - A sensitive and selective spectrofluorimetric method has been developed for the rapid determination of aluminium. This method is based on the formation of a complex between aluminium and N-((2-hydroxynaphthalen-1-yl)methylene) acetylhydrazide (HNMA). The fluorescence of the complex is monitored at an emission wavelength of 450 nm with excitation at 385 nm. Optimum complex formation occurred in Tris buffer at pH 6.0. Under the optimum conditions, linear calibration curves were obtained from 50 to 800 ppb. The detection limit was 9.2 ppb (ng mL−1). The maximum relative standard deviation of the method for an aluminium standard of 200 ppb was 2.5%. The effects of surfactants and interference from other ions were studied. The method was successfully applied for the determination of aluminium ions in water samples.
AB - A sensitive and selective spectrofluorimetric method has been developed for the rapid determination of aluminium. This method is based on the formation of a complex between aluminium and N-((2-hydroxynaphthalen-1-yl)methylene) acetylhydrazide (HNMA). The fluorescence of the complex is monitored at an emission wavelength of 450 nm with excitation at 385 nm. Optimum complex formation occurred in Tris buffer at pH 6.0. Under the optimum conditions, linear calibration curves were obtained from 50 to 800 ppb. The detection limit was 9.2 ppb (ng mL−1). The maximum relative standard deviation of the method for an aluminium standard of 200 ppb was 2.5%. The effects of surfactants and interference from other ions were studied. The method was successfully applied for the determination of aluminium ions in water samples.
KW - Aluminium
KW - Complex formation
KW - N-((2-hydroxynaphthalen-1-yl)methylene) acetylhydrazide (HNMA)
KW - Spectrofluorimetric determination
UR - http://www.scopus.com/inward/record.url?scp=85031719391&partnerID=8YFLogxK
UR - http://www.scopus.com/inward/citedby.url?scp=85031719391&partnerID=8YFLogxK
U2 - 10.1016/j.jtusci.2015.03.009
DO - 10.1016/j.jtusci.2015.03.009
M3 - Article
AN - SCOPUS:85031719391
SN - 1658-3655
VL - 9
SP - 601
EP - 609
JO - Journal of Taibah University for Science
JF - Journal of Taibah University for Science
IS - 4
ER -