Establishment of diagnostic reference levels in computed tomography in two large hospitals in Oman

Yassine Bouchareb*, Amal Al-Maimani, Al Yaqin Al-Balushi, Maather Al-Kalbani, Hasina Al-Maskari, Humoud Al-Dhuhli, Faiza Al-Kindi

*المؤلف المقابل لهذا العمل

نتاج البحث: المساهمة في مجلةArticleمراجعة النظراء

ملخص

This study aimed to estimate diagnostic reference levels (DRLs) for the most frequent computed tomography (CT) imaging examinations to monitor and better control radiation doses delivered to patients. Seven CT imaging examinations: Head, Chest, Chest High Resolution (CHR), Abdomen Pelvis (AP), Chest Abdomen Pelvis (CAP), Kidneys Ureters Bladder (KUB) and Cardiac, were considered. CT dosimetric quantities and patient demographics were collected from data storage systems. Local typical values for DRLs were calculated for CTDIvol (mGy), dose length product (DLP) (mGy·cm) and effective doses (mSv) were estimated for each examination. The calculated DRLs were given as (median CTDIvol (mGy):median DLP (mGy·cm)): Head: 39:657; Chest: 13:451; CHR: 6:228; AP: 12:578; CAP: 20:807; KUB: 7:315, and Cardiac: 2:31. Estimated effective doses for Head, Chest, CHR, AP, CAP, KUB and Cardiac were 1.3, 12.7, 6.3, 12.5, 18.1, 5.8 and 0.8 mSv, respectively. The estimated DRLs will act as guidance doses to prevent systematic excess of patient doses.

اللغة الأصليةEnglish
الصفحات (من إلى)2148-2155
عدد الصفحات8
دوريةRadiation Protection Dosimetry
مستوى الصوت199
رقم الإصدار17
المعرِّفات الرقمية للأشياء
حالة النشرPublished - أكتوبر 1 2023

ASJC Scopus subject areas

  • ???subjectarea.asjc.3600.3614???
  • ???subjectarea.asjc.3100.3108???
  • ???subjectarea.asjc.2700.2741???
  • ???subjectarea.asjc.2700.2739???